Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Reconciling mean-squared radius differences in the silver chain through improved measurement and ab initio calculations

Ohayon, B., Padilla-Castillo, J. E., Wright, S., Meijer, G., & Sahoo, B. K. (2024). Reconciling mean-squared radius differences in the silver chain through improved measurement and ab initio calculations. Physical Review Research, 6(3): 033040. doi:10.1103/PhysRevResearch.6.033040.

Item is

Dateien

einblenden: Dateien
ausblenden: Dateien
:
PhysRevResearch.6.033040.pdf (Verlagsversion), 593KB
Name:
PhysRevResearch.6.033040.pdf
Beschreibung:
-
OA-Status:
Gold
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
2024
Copyright Info:
The Author(s)

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Ohayon, B., Autor
Padilla-Castillo, J. Eduardo1, Autor                 
Wright, Sidney1, Autor                 
Meijer, Gerard1, Autor                 
Sahoo, B. K., Autor
Affiliations:
1Molecular Physics, Fritz Haber Institute, Max Planck Society, ou_634545              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Nuclear charge radius differences in the silver isotopic chain have been reported through different combinations of experiment and theory, exhibiting a tension of two combined standard errors. This study investigates this issue by combining high-accuracy calculations for six low-lying states of atomic silver with an improved measurement of the 5s2S1/2 − 5p2P3/2 transition optical isotope shift. Our calculations predict measured electronic transition energies in Ag I at the 0.3% level, the highest accuracy achieved in this system so far. We calculate electronic isotope shift factors by employing analytical response relativistic coupled-cluster theory and find that a consistent charge radius difference between 107,109Ag is returned when combining our calculations with the available optical isotope shift measurements. We therefore recommend an improved value for the mean-squared charge radius difference between 107Ag and 109Ag as 0.207(6) fm2, within one combined error from the value derived from muonic Ag experiments, and an updated set of charge radii differences across the isotopic chain.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2024-02-192024-06-112024-07-082024-07
 Publikationsstatus: Erschienen
 Seiten: 15
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1103/PhysRevResearch.6.033040
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Physical Review Research
  Kurztitel : Phys. Rev. Research
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: College Park, Maryland, United States : American Physical Society (APS)
Seiten: 15 Band / Heft: 6 (3) Artikelnummer: 033040 Start- / Endseite: - Identifikator: ISSN: 2643-1564
CoNE: https://pure.mpg.de/cone/journals/resource/2643-1564
OSZAR »